PROPERTY & LEASING
The following documents have been assembled to assist you in applying for a new lease at Falls Creek Alpine Resort.
STAKEHOLDER RESOURCES
BUILDING
There are many things to consider before starting your building, such as whether your job requires a building permit or a planning permit (or both). The Building Act 1993 (the Act) and Building Regulations 2018 (the Regulations) legislate that all building work is subject to the issuing of a building permit, unless an exemption exists for the proposed work under the Regulations. This includes some minor alterations, demolitions and repair or maintenance work.
A building permit will specify that either an occupancy permit is required or a certificate of final inspection is required on completion of the building work. If you are unsure please consult FCRM Municipal Building Surveyor whether your proposed building work requires a building permit.
Fire Orders must be displayed in a suitable location near or on the rear of the main entrance door of each bedroom (for lodge style accommodation) or near or on the rear of the main entrance door of an apartment (for apartment style accommodation), be clearly marked “Fire Orders” and the plan must be correctly orientated to minimize confusion in the case of emergency. Fire Orders must explain:
- the method of operation of all call points and the location of all call points if installed
- the location and methods of operation of all firefighting equipment
- the location of all exits and the assembly point at which the building occupants are to meet
- the procedure for evacuation of the building
- emergency services contact details such as the 000 number to be listed indicating that this is the number to call for fire, ambulance or police assistance.
AS 3959 – Bushfire Policy for All Lease Renewals with Existing Buildings Falls Creek Resort Management (FCRM) has developed an AS 3959 - Bushfire Risk Assessment Policy which is applied as part of the New Lease process. The policy has been developed in order to provide for minimum safety maintenance and upgrade requirements on existing buildings.
AS 3959 is a thorough and wide-reaching code designed to provide adequate safety and functionality to buildings. The Standard and this policy is designed to aid building professionals in their assessment of buildings and preparation of documentation supporting the lease renewal application in relation to plans, scope of works required and specifications.
The Boards Municipal Building Surveyor is charged with the responsibility of undertaking all bushfire risk assessments throughout the Village. This assessment is used during the new lease application process to determine required building works for inclusion in the new lease.
Elements assessed during Bushfire Risk Assessments are in accordance with the FCARMB adopted Guidelines.
Falls Creek Resort Management (FCRM) is charged with the responsibility for administering leasing obligations under the Alpine Resorts (Management) Act 1997 and the administration and enforcement of parts 3, 4, 5, 7 and 8 of the Building Act 1993. FCRM Municipal Building Surveyor can provide a number of services related to leasing obligations at a fee as outlined in the attached table. Please contact Falls Creek Resort Management directly for further information.
Charges applicable to Lessees can be separated into three main components:
- New Lease report requirements,
- Major and minor development works, and
- General building and maintenance works.
ESSENTIAL SAFETY MEASURES
What ESM's Are
ESM Stands for Essential Safety Measure. These are the installations and features incorporated into your building in order to keep its occupants safe, particularly in the event of an emergency. ESM's are important for keeping yourself and your customers safe, there are reporting requirements for most classes of premises.
ESM’s are established by the Building Act (Vic) 1993 and the Building Regulations (Vic) 2018 and are generally outlined in your building's Occupancy Permit and noted in your triennial Building Standards Reports.
Below is a list of Essential Safety Measures that are listed in your buildings Building Standards of Occupancy Inspection Report. Notes on how to perform and who is required to complete each item is available in the table below by clicking on the link. Please check your Building Standards Report for which items are relevant to your building. This information is also available on the Victorian Building Authority website www.vba.vic.gov.au.
Essential safety measure to be inspected or tested | Installation standard or level of performance | Nature of inspection or test frequency |
---|---|---|
Exit Signs | BCA D1.12, E4.5, E4.6, E4.8, G4.4 Click here for notes on what is required | Every six months to AS 2293-2005 |
Emergency Lighting | BCA E4.2, E4.4, G4.4 Click here for notes on what is required | Every six months to AS 2293-2005 |
Smoke and heat alarm system | Clause 3 of Specification E2.2a Click here for notes on what is required Clause 4 of Spectification E2.2a (fire panel system) Click here for notes on what is required | Monthly as prescribed in AS 1851-2012, Section 6 |
Fire hose reels | BCA E1.4 Click here for notes on how to perform inspection | Every six months to AS 1851-2012, Section 14 |
Fire extinguishers | BCA E1.6 Click here for notes on how to perform inspection | Every six months to AS 1851-2012, Section 15.4 |
Exit doors | BCA Section D Click here for notes on how to perform inspection | Inspection every three months to ensure doors are intact, operational and fitted with conforming hardware |
Paths of travel to an exit | BCA D1.6 Click here for notes on how to perform inspection | Inspection every three months to ensure there are no obstructions and no alterations. |
Building elements required to satisfy prescribed fire resistance levels | BCA Section C, D1.12 Click here for notes on how to perform inspection | Annual inspection for damage, deterioration or unauthorised alteration |
Materials and assemblies required to satisfy fire hazard properties | BCA C1.10 Click here for notes on how to perform inspection | Annual inspection for damage, deterioration or unauthorised alteration |
Solid core doors and self-closing mechanisms | BCA C3.11 Click here for notes on how to perform inspection | Annual inspection for damage, deterioration and check operation of closers |
Fire orders | G4.9 Click here for notes on how to perform inspection | Annual inspection to ensure warning sign is in place and legible |
Penetrations in fire rated structures | BCA C3.15 Click here for notes on how to perform inspection | Annual inspection for damage, deterioration or unauthorised alteration |
Signs on doors alerting people that they open inwards | G4.9 Click here for notes on how to perform inspection | Annual inspection to ensure warning sign is in place and legible |
- Practice note
- ESM Manual
- Template annual report
- Sample annual report
- Presentation
- Essential Safety Measures - How and Why to Maintain Your Compliance
When you need to register your pool or spa
To improve the safety of pools and spas, the Victorian regulations changed on 1 December 2019. From this date, if you own a property with a pool or spa, you’re required to register the pool/spa with FCRM by 1 November 2020.
How to register
Register your pool or outdoor spa using the Pool & Spa Registration Form. In the form, you'll need to provide the estimated date that the pool or spa was constructed, which will be reviewed by FCARMB.
Pool and spa certificate of compliance
Once your swimming pool or spa has been registered, you need to arrange an inspection of the safety barrier to determine if the barrier is compliant with the applicable barrier standard.
In addition, owners are now required to obtain and lodge a compliance certificate for the safety of their pool or spa barrier every four years by a building surveyor.
Schedule of Fees
Type of fee or penalty | Amount |
---|---|
Maximum fee for lodging a certificate of barrier compliance with FCRM | $20.80 |
Maximum fee for lodging a certificate of barrier non-compliance with FCRM | $390.80 |
Failure to lodge certificate of barrier compliance by date specified | up to $1,817.40 |
Failure to lodge certificate of barrier non-compliance by date specified | up to $1,817.40 |
Failure to comply with barrier improvement notice by date specified | up to $1,817.40 |
Find out more about:
- new pool and spa registration requirements
- pool and spa inspection and compliance
- pool safety barriers
- installing a new pool or spa
For more information: vba.vic.gov.au/swimming-pools
The (Access to Premises - Buildings) Standards 2010 (Premises Standards) have been developed under the Disability Discrimination Act 1992 (Cth) to ensure that dignified, equitable, cost-effective and reasonably achievable access to buildings is provided for people with a disability. It is important that all building practitioners and other associated parties are familiar and complying with these standards.
The attached practice note and accompanying word document provides further information on the Building Code of Australia Access requirements to ensure buildings and works to buildings are consistent with the statutory requirements and also ensuring people with a disability are able to access buildings in a dignified and equitable way.
Access to Buildings for people with a disability - Practice Note 14 from the VBA
Asbestos management for commercial property owners
If you are a commercial property owner who leases or rents, for example, a building or part of a building to a business or businesses, then you may have obligations under the Occupational Health and Safety Act 2004 and the Occupational Health and Safety Regulations 2017 to the extent of your management or control.
The links below provide detailed information about your responsibilities for managing asbestos:
Asbestos register
When asbestos is identified in a workplace, you need to create an asbestos register.
The asbestos register must be kept current and include:
- the location of the asbestos
- the likely source of asbestos that is not fixed or installed
- the type of asbestos containing material
-
- whether the asbestos containing material is friable or non-friable
- the condition of the asbestos-containing material
- whether the asbestos-containing material is likely to sustain damage or deterioration
- details of the location and likely source of asbestos that is not fixed or installed in relation to all inaccessible areas that may contain asbestos
- so far as possible detailed information about activities likely to be carried out in the workplace that are likely to damage or disturb the asbestos.
Examples of asbestos registers can be found HERE.
More information
For more information on the risks of asbestos and how to comply with the legal duties you can visit the following websites:
PLANNING
The Minister for Planning is the responsible authority for planning applications in Falls Creek Alpine Resort. This means that the Minister is responsible for the application process and making a decision.
Falls Creek Alpine Resort Management Board is a referral authority under Section 55 of the Planning and Environment Act 1987 and has the opportunity to comment on planning permit applications as the Land Manager.
Planning permits are legal documents giving permission for a land use or development, and may be required under the Alpine Resorts Planning Scheme. If a planning permit is required, it must be obtained before a building permit can be issued, however, both applications can be made at the same time. A planning permit does not remove the need to obtain a building permit.
The best way to find out whether you need a planning permit is to contact DELWP Development Approvals on 1800 789 386, or Falls Creek Resort Management directly.